中华医学杂志
2022年 · 第102卷第09期
中华医学杂志
关注马拉松运动骨肌损伤的影像学研究
肺电阻抗成像技术在重症呼吸管理中的临床应用中国专家共识
超短回波时间T2*成分分析技术在业余马拉松运动员跟腱形态及生化变化动态监测中的应用
半程马拉松运动后业余运动员髌腱形态特征动态变化的MRI表现分析
磁共振扩散张量成像定量评估半程马拉松运动对男性业余运动员大腿肌群的影响
基于MRI T2弛豫时间参数图的业余马拉松运动员比赛前后膝关节周围肌肉T2值变化特征分析
基于剪切波弹性成像的业余马拉松运动员比赛前后髌腱弹性变化定量分析
大学生长途徒步拉练对膝关节急性损伤及软骨亚区影响的MRI定量分析
全身麻醉经口气管插管下颈椎后路手术后Tapia综合征的发生及其相关因素
左房增大对急性缺血性脑卒中预后的影响
业余半程马拉松运动员足部损伤的MRI表现
基于CT灰度值赋予材料属性的马拉松运动员髋关节有限元模型建立及其应力分析
超短回波时间磁共振成像和压痕测试评估正常人踝关节标本跟腱和附着点的研究
The lesions of tendons, ligaments and their attachment points are closely related to many inflammatory and degenerative diseases of the musculoskeletal system. MRI has great advantages in the diagnosis of osteomuscular and soft tissue lesions because of its good tissue resolution, but the transverse relaxation time of normal tendons and attachment points (T2At present, conventional MRI sequences have almost no signal, which brings great difficulties to the study of MRI characteristics of tendons and attachment points. The study used a novel 3.0 T magnetic resonance three-dimensional ultrashort echo time (3D UTE) sequence and a 11.7 T conventional MRI sequence to display normal tendon and attachment point structures. In this study, five ankle specimens [2 males and 3 females, mean age (35.4 ± 5.0) years] were scanned using a 3D UTE sequence of 3.0 T magnetic resonance to investigate the T of the Achilles tendon and attachment points2*, T1And magnetization transfer rate (MTR), and macromolecular proton component MT modeling was performed. At the same time, it was morphologically observed using 11.7 T conventional MRI sequence, and the mechanical properties of Achilles tendon and attachment points were studied by indentation test, and histological analysis was performed by pathological sections. T of the Achilles tendon and attachment point2*Values were (0.93 ± 0.48) ms and (2.77 ± 0.79) ms, respectively, T1The values were (644 ± 22) ms and (780 ± 55) ms, the MTR was 0.373 ± 0.030 and 0.244 ± 0.009, the average power was 1 000°, the frequency offset was 2 kHz, and the macromolecular proton fraction was (18.0 ± 2.2) % and (13.9 ± 1.9) %, respectively. Compared to the Achilles tendon, the attachment point usually has a longer T2* and T1Values, lower MTR and macromolecular proton fraction, and higher Young's modulus and stiffness. This study provides baseline values for the Achilles tendon and attachment sites in normal subjects, which can be used for the diagnosis of seronegative arthritis and other terminal diseases.
具有可量化站立位负重面积的股骨近端有限元建模
Finite element technology plays an important role in digitized orthopedic research. Among them, as the largest weight-bearing joint in human body, the finite element analysis related to hip joint has been the focus of research. The researchers conducted mechanical studies on the standing hip joint model and realized that in the standing posture, the contact area of the femoral head and the weight-bearing area are the direct acting surfaces of forces, and their position distribution and magnitude directly affect the stress distribution of the femoral head. However, in most studies related to FEM of the femur, the division of this region is vague, imprecise, and non-individualized. To investigate the effect of the load-bearing area of the femoral head in the standing position and the positional distribution and magnitude of the direct moving surface of the force on the results of finite element analysis, five adult volunteers were recruited for X-ray and CT examination with a patented device in the same simulated bipedal standing position. The two-dimensional weight-bearing area on the X-ray image is calculated, and the three-dimensional model of proximal femur is reconstructed according to the CT data, and it is registered to realize the conversion from the two-dimensional weight-bearing area to the three-dimensional quantized area. One of the three-dimensional models of the proximal femur was randomly selected for finite element analysis, three different loading surfaces were defined, and their finite element results were compared. The results showed that five volunteers constructed a total of 10 weight-bearing surfaces, mainly distributed in crescent shape in the dome and anterolateral side of the femoral head, ranging from 1 218.63~1 871.06 mm2。 The stress magnitude and distribution of the proximal femur finite element model are significantly different under three different loading conditions, and the loading conditions of quantifying the load-bearing area are more in line with the physical phenomena of the hip. In this study, a set of simple methods was used to quantify the position distribution and size of the weight-bearing area of the femoral head while standing, and the individualized reconstruction of the proximal femoral finite element model was realized. This method can define more reasonable load surface settings without increasing the difficulty of actual modeling.
本期目次

